Gas-Steam Power Plant Mellach
The electric steam superheaters have been designed to feed gas turbines with superheated steam for start-up and low load in the gas-steam power plant Mellach. They dispose of a high degree of automation and are easy to operate. The steam superheaters have been developed as standard components and each of them is equipped with two redundant switchboard panels switching automatically in case of disruption.
Technical Data
- heating power P=240kW
- steam temperature: up to 270 °C
- connection voltage: max. 690 V/AC
Manufacturing Standards
- PED 97/23/EG
- EN 12953
- EN 13445
- GOST TR, RTN
- ASME VIII DIV.1